Anaesthesia System Encore 755

Email
Rating: Not Rated Yet
Description

1.0621 Encore 755 Anaesthetia System

1.0621 Encore 755 Anaesthetia System

Features

5.7″TFT colour LCD screen, 640x480 pixels

2 x drawers 200x392x398mm (HxWxD) *NEW "soft close"

Suitable for paediatric & adult use

Integrated absorber system with heating function, bypass design, easy assembly, autoclavable

Audiovisual alarms

Built-in battery

Built in expiratory PEEP valve

Gas supply: O2, N2O, Air

Dimensions (HxWxD): 1410x950x650mm, 110Kg

Maximum load on top: 30kg

Electrical Specification

Mains: 100-240V AC. 50Hz/60Hz

Battery type: NiMH 12V DC

Battery minimum supply time: 4 hours

Battery charge time: 4 hours

3 auxiliary output power interface

Flowmeter

6 tubes flowmeter

0.05~10 l/min

Gas system:

Hypoxic guard system

O2 flush

Ventilator

Patient type: Adult & Paediatric

Ventilation modes: VCV, Manual, Standby (PCV Optional)

Tidal volume: 50~1500ml

 

Respiratory System

Absorber Canister Capacity: About 1,500ml

Connection: Inhalation/Exhalation ports: standard OD 22mm, ID 15mm; tapered connector

Manual breathing bladder port: standard OD 22mm

System leak: <140ml/min

Respiratory system resistance: Inspiratory/expiratory: <0.6kPa

Parameters Setting

Tidal volume: Range 50-1,500ml

Tidal Volume Increment: 50~100ml: 5ml; 100~1,500ml: 10ml

Respiratory rate: Range:1~100bpm; increment: 1bpm

Inspiratory time: Range: 0.1~10.0s; increment: 0.1s

Respiratory ratio: Range: 4:1 to 1:10; increments: 0.5

Percentage of inspiratory pause: Range: 0 to 50%; increment: 5%

PEEP: Range: OFF, 3~30cmH2O; increment: 1cmH2O

Pressure Support: Range: 0~70cmH2O; increment: 1cmH2O

Pressure Control: Range: 5~70cmH2O; increment: 1cmH2O

Flow trigger: Range: 0.5~20l/min; increment: 0.1l/min

Pressure trigger: Range: 0~20cmH2O; increment: 0.1cmH2O

Monitoring Parameters

Inspiratory tidal volume: 0~2,500ml

Expiratory tidal volume: 0~2,500ml

Minute volume: 0~60 l/min

Spont minute volume: 0~60 l/min

Respiratory rate: 0~100bpm

Spontaneous breathing frequency: 0~100bpm

Respiratory ratio: 30:1 to 1:150

Peak airway pressure: 0~100cmH2O

Mean airway pressure: : 0~100cmH2O

PEEP: 0~100cmH2O

Inspiratory plateau pressure: 0~100cmH2O

FiO2 (optional): 15 to 100%

Compliance: 0~300 ml/cmH2O

Airway resistance: 0~600cmH2O / (L/S)

EtCO2 (optional): 0~100mmHg

Alarm

 MV, Paw, Continuous Paw high, Vte, Rate, FiO2, Mains failure, Battery low, Battery discharged, Gas supply failure, O2 supply failure, Apnoea

Tidal volume: High: 30~2,000ml, OFF; Low: 20~1,500ml

Minute ventilation: High: 1~99l; Low: 0~98l

Respiratory rate: High: 1~100bpm; Low: 0~99bpm

FiO2 (optional): High: 22~100% OFF; Low: 20~99%

Airway pressure: High: 10~99cmH2O; Low: 1~98cmH2O

Continuous positive airway pressure

Negative pressure alarm: Airway pressure is less than –10cmH2O

Oxygen deficiency alarm: Oxygen pressure is less than 0.28MPa; alarm sound pressure level of not less than 60dB

Alarm mute: ≤120s

Inhaled oxygen concentration <18%: FiO2<18% Vol

Measurement

Pressure values: Pmin, Ppeak, Pplat, Pmean, PEEP

Volume/Flow values: MV, Vti, Vte, MVspn

Loops: Pressure-Volume, Volume-Flow

FiO2, f, fspn, Rst, Cdyn

Waveform: Paw, Flow, Volume 

 

 

 

 